Radiologic Comparison of Humeral Position according to the Implant Designs Following Reverse Shoulder Arthroplasty: Analysis between Medial Glenoid/Medial Humerus, Lateral Glenoid/Medial Humerus, and Medial Glenoid/Lateral Humerus Designs
10.5397/cise.2018.21.4.192
- Author:
Nam Su CHO
1
;
Ju Hyun NAM
;
Se Jung HONG
;
Tae Wook KIM
;
Myeong Gu LEE
;
Jung Tae AHN
;
Yong Girl RHEE
Author Information
1. Shoulder & Elbow Clinic, Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, Seoul, Korea. nscos1212@empas.com
- Publication Type:Original Article
- Keywords:
Shoulder;
Cuff tear arthropathy;
Massive rotator cuff tear;
Reverse shoulder arthroplasty;
Implant design
- MeSH:
Arthroplasty;
Humans;
Humerus;
Prosthesis Design;
Retrospective Studies;
Shoulder
- From:Clinics in Shoulder and Elbow
2018;21(4):192-199
- CountryRepublic of Korea
- Language:English
-
Abstract:
BACKGROUND: The currently available reverse shoulder arthroplasty (RSA) designs can be classified into medial glenoid/medial humerus (MGMH), lateral glenoid/medial humerus (LGMH), and medial glenoid/lateral humerus (MGLH) prosthesis designs. The purpose of this study was to radiologically analyze the effect of different RSA designs on humeral position following RSA. METHODS: A total of 50 patients who underwent primary RSA were retrospectively analyzed. Among 50 patients, 33 patients (group A: MGMH) underwent RSA with Aequalis system (Wright, Inc, Bloomington, MN, USA), 6 (group B: LGMH) with Aequalis system using bony increased offset, and 11 (group C: MGLH) with Aequalis Ascend Flex system. The acromiohumeral distance, acromioepiphyseal distance (AED), lateral humeral offset (LHO), LHO from the center of rotation (LHO(COR)), and deltoid length were radiologically measured to quantify the distalization and lateralization of the humerus. RESULTS: The increment in postoperative AED was 19.92 ± 3.93 mm in group A, 24.52 ± 5.25 mm in group B, and 25.97 ± 5.29 mm in group C, respectively (p=0.001). The increment in postoperative LHO was 0.13 ± 6.30 mm, 8.00 ± 12.14 mm, and 7.42 ± 6.88 mm, respectively (p=0.005). The increment in postoperative LHOCOR was 20.76 ± 6.06 mm, 22.04 ± 5.15 mm, and 28.11 ± 4.14 mm, respectively (p=0.002). CONCLUSIONS: The radiologic analysis of the effect of different RSA designs on humeral position following RSA showed significant differences in the increment in postoperative AED, LHO, and LHO(COR) between the 3 groups. Therefore, MGLH design seems to be more effective for humeral distalization and lateralization compared to original Grammont design.