Safety and Efficacy of Biodegradable Polymer-biolimus-eluting Stents (BP-BES) Compared with Durable Polymer-everolimus-eluting Stents (DP-EES) in Patients Undergoing Complex Percutaneous Coronary Intervention
- Author:
Pil Sang SONG
1
;
Kyu Tae PARK
;
Min Jeong KIM
;
Ki Hyun JEON
;
Jin Sik PARK
;
Rak Kyeong CHOI
;
Young Bin SONG
;
Seung Hyuk CHOI
;
Jin Ho CHOI
;
Sang Hoon LEE
;
Hyeon Cheol GWON
;
Jin Ok JEONG
;
Eul Soon IM
;
Sang Wook KIM
;
Woo Jung CHUN
;
Ju Hyeon OH
;
Joo Yong HAHN
Author Information
- Publication Type:Original Article
- Keywords: Coronary artery disease; Percutaneous coronary intervention; Drug-eluting stents
- MeSH: Coronary Artery Disease; Death; Drug-Eluting Stents; Follow-Up Studies; Humans; Myocardial Infarction; Percutaneous Coronary Intervention; Stents
- From:Korean Circulation Journal 2019;49(1):69-80
- CountryRepublic of Korea
- Language:English
- Abstract: BACKGROUND AND OBJECTIVES: There are no data comparing clinical outcomes of complex percutaneous coronary intervention (PCI) between biodegradable polymer-biolimus-eluting stents (BP-BES) and durable polymer-everolimus-eluting stents (DP-EES). We sought to evaluate the safety and efficacy of BP-BES compared with DP-EES in patients undergoing complex PCI. METHODS: Patients enrolled in the SMART-DESK registry were stratified into 2 categories based on the complexity of PCI. Complex PCI was defined as having at least one of the following features: unprotected left main lesion, ≥2 lesions treated, total stent length >40 mm, minimal stent diameter ≤2.5 mm, or bifurcation as target lesion. The primary outcome was target lesion failure (TLF), defined as a composite of cardiac death, target vessel-related myocardial infarction (TV-MI), or target lesion revascularization (TLR) at 2 years of follow-up. RESULTS: Of 1,999 patients, 1,145 (57.3%) underwent complex PCI: 521 patients were treated with BP-BES and 624 with DP-EES. In propensity-score matching analysis (481 pairs), the risks of TLF (3.8% vs. 5.2%, adjusted hazard ratio [HR], 0.578; 95% confidence interval [CI], 0.246–1.359; p=0.209), cardiac death (2.5% vs. 2.5%, adjusted HR, 0.787; 95% CI, 0.244–2.539; p=0.689), TV-MI (0.5% vs. 0.4%, adjusted HR, 1.128; 95% CI, 0.157–8.093; p=0.905), and TLR (1.1% vs. 2.9%, adjusted HR, 0.390; 95% CI, 0.139–1.095; p=0.074) did not differ between 2 stent groups after complex PCI. CONCLUSIONS: Clinical outcomes of BP-BES were comparable to those of DP-EES at 2 years after complex PCI. Our data suggest that use of BP-BES is acceptable, even for complex PCI.