Computational Fluid Dynamics of Intracranial and Extracranal Arteries using 3-Dimensional Angiography: Technical Considerations with Physician's Point of View.
10.5469/neuroint.2013.8.2.92
- Author:
Sung Tae PARK
1
;
Kyunghwan YOON
;
Young Bae KO
;
Dae Chul SUH
Author Information
1. Department of Radiology, Soonchunhyang University Hospital, Seoul, Korea. stpark@schmc.ac.kr
- Publication Type:Case Report
- Keywords:
Hemodynamics;
Angiography;
Carotid Arteries
- MeSH:
Angiography;
Arteries;
Carotid Arteries;
Hemodynamics;
Humans;
Hydrodynamics
- From:Neurointervention
2013;8(2):92-100
- CountryRepublic of Korea
- Language:English
-
Abstract:
We investigate the potentials and limitations of computational fluid dynamics (CFD) analysis of patient specific models from 3D angiographies. There are many technical problems in acquisition of proper vascular models, in pre-processing for making 2D surface and 3D volume meshes and also in post-processing steps for display the CFD analysis. We hope that our study could serves as a technical reference to validating other tools and CFD results.