Emergent Endovascular Treatment of Ruptured Dissecting Aneurysm of the Intradural Vertebral Artery Using a Self-Expandable Intracranial Stent and a Bioactive Hydrophilic coil.
- Author:
Sang Il SUH
1
;
Hae Young SEOL
;
Taik Kun KIM
;
Nam Joon LEE
;
Jung Hyuk KIM
;
Taek Hyun KWON
Author Information
1. Department of Diagnostic Radiology, Korea University College of Medicine, Korea. seol@korea.ac.kr
- Publication Type:Case Report
- Keywords:
Vertebral artery;
Coil embolization;
Dissecting Aneurysm;
Stent
- MeSH:
Aneurysm;
Aneurysm, Dissecting*;
Arteries;
Embolization, Therapeutic;
Humans;
Parents;
Stents*;
Vertebral Artery*
- From:Neurointervention
2007;2(2):109-112
- CountryRepublic of Korea
- Language:English
-
Abstract:
Ruptured dissecting aneurysm of the vertebral artery requires a rapid treatment because of the high rate of fatal early rebleeding. Stent-assisted coil embolization has been introduced as an effective procedure for both aneurysmal occlusion and parent artery preservation. We report a case of successful urgent treatment of ruptured dissecting aneurysm using a self-expandable, intracranial stent (Neuroform(R)) and a coated coil (HydroCoil(R)).