Clinical value of the plasma circular RNA hsa_circ_0009024 in the diagnosis and treatment of pulmonary tuberculosis
10.3760/cma.j.issn.1009-9158.2018.05.015
- VernacularTitle:血浆环状RNA hsa_circ_0009024表达在肺结核诊疗中的应用价值
- Author:
Zikun HUANG
1
;
Qingshui HUANG
;
Qing LUO
;
Fangyi YAO
;
Yiping PENG
;
Jianqing XU
;
Lu ZHANG
;
Junming LI
Author Information
1. 330006,南昌大学第一附属医院检验科
- Keywords:
Tuberculosis,pulmonary;
RNA;
Biomarkers
- From:
Chinese Journal of Laboratory Medicine
2018;41(5):399-404
- CountryChina
- Language:Chinese
-
Abstract:
Objective Detecting plasma level of circular RNA(circRNA)hsa_circ_0009024 in pulmonary tuberculosis(TB)patients,and evaluating its diagnostic value for TB.Methods From January 2016 to December 2016, a hosptial-based, case-control study was performed, which include 90 untreated active pulmonary tuberculosis patients(TB group),75 healthy people(healthy control)and 84 patient with other diseases(other disease group).Plasma level of circRNA hsa_circ_0009024 was detected by real-time quantitative polymerase chain reaction.Furthermore, the 90 patients with TB were divided into different subgroups according to cavity formation and the lung fields involvement: patients without lung cavity(55 cases)vs those with lung cavity(35 cases),patients with involvement of <2 lung fields(49 cases)vs≥2 lung fields(41 cases).Plasma levels of hsa _circ_0009024 of 41 TB patientswere monitored andcomparedbefore and after 3 months anti-TB therapy.The sensitivity and specificity of plasma hsa_circ_0009024 were analyzed by using the receiver operating characteristic(ROC)curve.The comparison between two groups was performed with Mann-Whitney U test and the comparison among multigroupswas conducted with Kruskal-Wallis H test.Results Plasma levels of hsa_circ_0009024 in TB patients[1.98(1.42, 2.71)]were significantly higher than healthy controls[1.03(0.78,1.33)]and other disease groups[1. 13(0.77,1.51)](H=76.58,P<0.0001).Plasma levels of hsa_circ_0009024 in cavity pulmonary TB patients were higher than pulmonary TB patients without cavity(U=392.50,P<0.0001).Plasma levels of hsa_circ_0009024 in TB patients with involvement of ≥2 lung fields were higher than <2 lung fields(U=590.50,P=0.0008).As compared to pre -treatment[2.01(1.41, 2.71)], the plasma hsa_circ_0009024 levels decreased significantly in 3 months[1.22(0.85,1.47)](U=292.50,P<0.0001)after anti-TB therapy.The area under the receiver operating characteristics curve(AUC)of plasma hsa_circ_0009024 in discriminating the patients with TB from normal controls, pneumonia patients and lung cancer patients were 0.841 and 0.811, respectively.Conclusion The hsa_circ_0009024 can be used as a potential biomarker in TB diagnosis and monitoring.