Comparison of efficacy and safety between thulium laser and high frequency electric knife on peroral endoscopic myotomy
10.3760/cma.j.issn.1007-5232.2018.06.003
- VernacularTitle:铥激光与高频电用于经口内镜下肌切开术的对比研究
- Author:
Chuxuan BIN
1
;
Haiyun SHI
;
Peng LI
;
Yongjun WANG
;
Shutian ZHANG
Author Information
1. 首都医科大学附属北京友谊医院消化内科
- Keywords:
Laser;
High frequency electric knife;
Achalasia;
Peroral endoscopic myotomy
- From:
Chinese Journal of Digestive Endoscopy
2018;35(6):391-395
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the efficacy and safety of 1 940 nm thulium laser on peroral endoscopic myotomy (POEM) for treatment of patients with achalasia of cardia. Methods Fifteen patients undergoing POEM in Beijing Friendship Hospital from February 2016 to November 2016 were enrolled and divided into 1 940 nm thulium laser group ( n=7) and high frequency electric knife group ( n=8) using zelen′s design, with followed-up for three months. The operation time, success rate, efficacy, and complications were compared between the two groups. Results All the procedures were successfully completed. There was no significant difference on baseline between the two groups ( P>0. 05). The time of total operation, creating submucosal tunnel, myotomy, and closing incision were not significantly different between the two groups (all P>0. 05). The bleeding amount, creating tunnel bleeding amount, and myotomy bleeding amount were not significantly different between the two groups (all P>0. 05). The complication rate during operation and one week after operation was not significantly different between the two groups ( P=0. 76).The time of creating mucosal incision for the 1 940 nm thulium laser group was longer than that of the high frequency electric knife group ( 3. 7 ± 3. 0 min VS 2. 3 ± 1. 3 min, P= 0. 02). After one month of follow-up, the efficiency of the 1 940 nm thulium laser group and the high frequency electric knife group was 100. 0%(7/7) and 87. 5%(7/8), respectively (P=0. 33), and the complication rate was 14. 3%(1/7) and 12. 5%(1/8), respectively (P=0. 92). After three months of follow-up, the efficiency of the two groups was 100. 0%(7/7) and 75. 0%( 6/8), respectively ( P=0. 16), and the complication rate was 28. 6%(2/7) and 12. 5%(1/8), respectively (P=0. 60). Conclusion 1 940 nm thulium laser and high frequency electric knife both have good utility on POEM.1 940 nm thulium laser decreases the operating time and bleeding compared with high frequency electric knife.