The value of cross raft screws technique to prevent postoperative collapse of tibial plateau fracture
10.3760/cma.j.issn.0253-2352.2018.15.001
- VernacularTitle:交叉排钉技术对防止胫骨外侧平台骨折术后关节面塌陷的价值
- Author:
Xi ZHANG
1
;
Jie SUN
;
Fangguo LI
;
Yongcheng HU
;
Baotong MA
;
Yandong LU
;
Jie LU
;
Lin GUO
;
Meng CUI
;
Xuelei WEI
;
Yunjiao LIU
Author Information
1. 300211,天津医院膝关节创伤骨科二病区
- Keywords:
Tibial fractures;
Fracture fixation,internal;
Treatment outcome
- From:
Chinese Journal of Orthopaedics
2018;38(15):897-904
- CountryChina
- Language:Chinese
-
Abstract:
Objective To assess the clinical value of cross raft screws technique in preventing postoperative collapse of tibial plateau fracture.Methods From September 2014 to November 2017,data of 14 patients with tibial plateau fracture who were treated by cross raft screws technique were retrospectively analyzed.There were 9 males and 5 females aged from 30-65 years old (average,44.4± 1.7 years).There were 8 patients that the thickness of subchondral cancellous bone measured preoperatively by CT data was less than 4 mm,and 6 patients that the thickness of subchondral cancellous bone measured intraoperatively was less than 4 mm.1/4 tubular plate was placed along the anterior rim of lateral tibial plateau,and the 3.5 mm cortical bone screws were fixed as bamboo raft from anterior to posterior through the plate.The collapse of tibial plateau after surgery were measured by CT scan after union of the fracture.The function of knee was evaluated by Rasmussen Anatomical and Functional Grading.Results The time of tubular plate procedure was 18 to 35 min (average,24.1±5.4 min).All 14 patients were successfully followed-up for 13.8±5.1 months.The height of collapse preoperatively by CT scan was 5-21 mm (average,8.00± 1.40 mm).3 days after the operation,the height between articular line and lateral articular surface was 0-2 mm (average,0.80±0.06 mm).Compared with CT data preoperatively,the collapse was corrected postoperatively that was proved by CT scan (P< 0.05).After the fracture was healed,according to CT data,the height between articular line and lateral articular surface was 0-2 mm (average,0.70±0.08 mm).Compared with CT data postoperatively,there was no postoperative collapse happened (P=0.466).The position and length of nails were placed appropriately.The average healing time of fracture was 3.6 months.There were no infection,nonunion and pain of tendon happened.The plate could be touched subcutaneously in 2 patients,who had no discomfort feelings.The patient's postoperative Rasmussen Anatomical Grading were 13-18 (average,16.7),including 8 cases excellent and 6 cases good.The postoperative Rasmussen Functional Grading was 18-28 (average,25.7),including 11 cases excellent and 3 cases good.Conclusion The cross raft screws technique is a good way to prevent the postoperative collapse of the lateral articular surface of tibial plateau.