Effects of different ultrasound power application on left ventricular rotation and twist in vivo open-chest beagle canines
10.3760/cma.j.issn.1004-4477.2018.09.017
- VernacularTitle:超声波辐照对比格犬左心室旋转和扭转运动影响的在体实验研究
- Author:
Wenhua LI
1
;
Lixue YIN
;
Hongmei ZHANG
;
Shu YANG
;
Jing LU
;
Junwang MIAO
;
Ni LIN
;
Yu HUANG
;
Geqi DING
;
Yan DENG
Author Information
1. 四川省医学科学院·四川省人民医院心血管超声及心功能科 超声心脏电生理学与生物力学四川省重点实验室
- Keywords:
Sonication;
Ventricular function,left;
Rotation;
Twist
- From:
Chinese Journal of Ultrasonography
2018;27(9):811-816
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate left ventricular ( LV ) myocardial mechanical rotation and twist with contrast agent and different power irradiation in open-chest beagle canines by ultrasound velocity vector images ( VVI ) . Methods The anesthetized open-chest Beagle canines were assigned into two groups randomly :group A ( n = 6 ) for baseline ,diagnostic ultrasound power irradiation ( 300 mW ) 5 min , combined with contrast agent irradiation 5 min and contrast agent 20 min conditions ;group B ( n = 6) for baseline and intensity ultrasound irradiation ( 1 W ,2 W and 3 W ,5 min respectively ) conditions . The standard short-axis gray-scale views at basal level (BL) ,and apical level( AL) during three complete cardiac cycles in open-chest beagle canine models were acquired . The peak subendomyocardium rotation ( subendo-rot) ,subepimyocardium rotation ( subepi-rot) of BL and AL were analyzed using a dedicated Syngo velocity vector imaging ( VVI) method and LV subendomyocardium twist ( subendo-twi) and subepimyocardium twist ( subepi-twi) were defined as apical subendo-rot/subepi-rot - basal subendo-rot/subepi-rot . Results In group A ,the LV subendo-twi ,subepi-twi ,subendo-rot and subepi-rot of BL and AL in the most of segments were significant different on diagnostic power irradiation ,contrast agent irradiation 5 min and contrast agent 20 min ( P < 0 .05 ) compared with baseline condition ;LV subendo-twi was higher than subepi-twi in group A under the same condition ( P < 0 .05) . In group B ,LV subendo-twi ,subepi-twi and subendo-rot ,subepi-rot of BL and AL on power 1 W ,2 W were higher and subendo-twi ,subepi-twi on power 3 W were lower than those on baseline condition ( P < 0 .05) ;There was no difference in subendo-rot and subepi-rot of LV BL compared with baseline condition ( P > 0 .05) ;subendo-rot and subepi-rot of LV AL were different compared with those on baseline condition ( P < 0 .05) ;LV subendo-twi and subepi-twi in group B under the same condition were significant difference ( P < 0 .05) . Conclusions LV rotation and twist increase on diagnostic ultrasound power irradiation 5 min ,combined with contrast agent irradiation 5 min ,contrast agent 20 min conditions ,1 W and 2 W ;LV twist and AL rotation decrease on ultrasound power 3 W ,but BL rotation is not affected on ultrasound power 3 W .