Effects of different ultrasound power application on left ventricular myocardium synchrony in vivo open -chest Beagle canines
10.3760/cma.j.issn.1004-4477.2018.08.021
- VernacularTitle:超声波辐照比格犬左心室心肌运动同步性的在体实验研究
- Author:
Wenhua LI
1
;
Lixue YIN
;
Hongmei ZHANG
;
Shu YANG
;
Jing LU
;
Junwang MIAO
;
Ni LIN
;
Yu HUANG
;
Geqi DING
;
Yan DENG
Author Information
1. 四川省医学科学院·四川省人民医院心血管超声及心功能科 超声心脏电生理学与生物力学四川省重点实验室
- Keywords:
Sonication;
Ventricular function,left;
Beagle canines;
Synchrony
- From:
Chinese Journal of Ultrasonography
2018;27(8):720-724
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate left ventricular ( LV ) myocardial mechanical synchrony with contrast agent and different power irradiation in open-chest Beagle canines . Methods The anesthetized open-chest Beagle canines were assigned into two groups randomly : Group A ( n = 6 ) for baseline , diagnostic ultrasound power irradiation ( 300 mW ) 5 min ,combined with contrast agent irradiation 5 min and contrast agent 20 min conditions ;Group B ( n = 6) for baseline and intensity ultrasound irradiation ( 1 W ,2 W and 3 W ,5 min respectively) conditions . The standard short-axis gray-scale views at levels of mitral annulus ( MV) ,papillary muscle( PM ) ,and apex( AP) during 3 complete cardiac cycles in open-chest Beagle canine models were acquired . The global radial displacement peak time ( RD-PT) and standard deviation of peak time ( RD-PT SD ) of LV subendomyocardium ( subendo ) and subepimyocardium ( subepi ) were measured and analyzed by using a dedicated Syngo velocity vector imaging ( VVI) method . Results In group A ,compared with baseline condition , the RD-PT and RD-PT SD of subendo and subepi had no significant different among diagnostic power irradiation ,contrast agent irradiation 5 min and contrast agent 20 min ( all P < 0 .05) . There was no significant different in the RD-PT and RD-PT SD between subendo and subepi in A group in all conditions ( all P < 0 .05) . In group B ,the RD-PT and RD-PT SD of subendo and subepi with power 1 W ,2 W and 3 W was higher than those with baseline condition ;the RD-PT and RD-PT SD of subendo were significant different on 2 W compared with those on baseline condition ( all P <0 .05) ;the RD-PT and RD-PT SD of subendo ,subepi were significant different on 3 W compared with baseline condition ( all P < 0 .05) ;the RD-PT and RD-PT SD were significant difference between subendo and subepi in only 3 W condition ( all P < 0 .05 ) . Conclusions Diagnostic ultrasound power irradiation 5 min and combined with contrast agent irradiation 5 min and contrast agent 20 min conditions do not effect the synchrony of LV myocardial mechanics . Power more than 1 W can induce the delay of RD-PT and RD-PT SD of LV subendo and subepi . Power 3 W can result in dyssynchrony of LV myocardial mechanics .