Systematic evaluation of repairing femoral defects by biomechanical measurements in rats
10.3760/cma.j.issn.1671-7600.2018.03.012
- VernacularTitle:系统性生物力学评价大鼠股骨缺损修复进程的实验研究
- Author:
Tianqing CAO
1
;
Pengzhen CHENG
;
Liu YANG
;
Shuaishuai ZHANG
;
Donglin LI
;
Yue SONG
;
Bin LIU
;
Hao WU
;
Guoxian PEI
Author Information
1. 空军军医大学西京医院骨科
- Keywords:
Femur;
Bone defects;
Biomechanics;
Rats
- From:
Chinese Journal of Orthopaedic Trauma
2018;20(3):247-253
- CountryChina
- Language:Chinese
-
Abstract:
Objective To systematically evaluate the biomechanical recovery of drilled holes in the femur in SD rats.Methods Eighteen female SD rats were randomized into 3 even groups (n =6).Models of 2-mm drilled holes in bilateral femurs were established in groups A and B with 2 holes on each side while no drilling was performed in group C.Samples were harvested in group A at postoperative 4 weeks,in group B at postoperative 8 weeks while at both 4 and 8 weeks in group C.The samples were evaluated in terms of linear elasticity (compression test),viscoelasticity (relaxation and creep tests) and durability (fatigue failure test).Micro-CT scan was performed to measure the bone volume fraction (BV/TV) and bone mineral density (BMD) of new bone.Sirus red staining was performed to measure regeneration of type Ⅰ collagen of new bone.Results The elasticity modulus,maximum load,compression strength and conditional yield limit in groups A were significantly lower than those in group B which were also significantly lower than those in group C (P < 0.05).At 7,200 s,the relaxation (14.56 ±0.69 MPa) and creep variation (11.37% ± 0.70%) in group A were significantly higher than those in group B (11.06 0.63 MPa and 8.98% ± 0.40%) which were also significantly higher than those in group C (6.99 ±0.56 MPa and 5.10% ±0.23%) (P < 0.05).At the constant amplitude loads from 20 N to 200 N,from 20 N to 300 N and from 20 N to 400 N,the recycling numbers in group A (6,044.3 ±879.7,4,093.3 ±628.5 and 1,919.3 ±847.5) were significantly lower than those in group B (10,192.3 ± 1,109.1,6,750.6 ± 818.0 and 3,376.6 ± 671.3) which were also significantly lower than those in group C (28,068.3 ±2,702.6,11,788.3 ± 1,141.6 and 5,296.3 ± 735.0) (P < 0.05).By micro-CT scan,the BVT and BMD in group A were significantly lower than those in group B which were also significantly lower than those in group C (P < 0.05).The sirus red staining showed the type Ⅰ collagen in the bone defect area was completely regenerated in group B.Conclusion Systematic biomechanical measurements may actually detect the characteristics of biomechanical recovery of bone holes in SD rats,enriching the basic research on the bone damage repairing progress.