Study on Quality Standard for Siwei Jiangmei Tablets
	    		
		   		
		   			 
		   		
	    	
    	 
    	10.6039/j.issn.1001-0408.2018.08.07
   		
        
        	
        		- VernacularTitle:四味降酶片的质量标准研究
- Author:
	        		
		        		
		        		
			        		Shixiao ZHANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Xingxing ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Xiangfen WANG
			        		
			        		;
		        		
		        		
		        		
			        		Heng LI
			        		
			        		
		        		
		        		
		        		
    Author Information Author Information
 
			        		
			        		
			        			1. 解放军第159医院药械科
 
 
- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Siwei jiangmei tablets;
			        		
			        		
			        		
				        		TLC;
			        		
			        		
			        		
				        		HPLC;
			        		
			        		
			        		
				        		Chlorogenic acid;
			        		
			        		
			        		
				        		Quality standard
			        		
			        		
	        			
        			
        		
- From:
	            		
	            			China Pharmacy
	            		
	            		 2018;29(8):1040-1043
	            	
            	
- CountryChina
- Language:Chinese
- 
		        	Abstract:
			       	
			       		
				        
				        	OBJECTIVE:To establish the quality standard for Siwei jiangmei tablets. METHODS:TLC method was used for the qualitative identification of Salvia miltiorrhiza,Artemisiae Scopariae Herba and Taraxaci Herba. HPLC method was adopted for the content determination of chlorogenic acid. The determination was performed on Agilents TC-C18column with mobile phase consisted of acetonitrile-3% acetic acid(10:90,V/V)at the flow rate of 1.0 mL/min. The detection wavelength was set at 327 nm,and column temperature was 25 ℃. The sample size was 10 μL. RESULTS:TLC spots of S. miltiorrhiza, Artemisiae Scopariae Herba and Taraxaci Herba were clear and well-separated without interference from negative control. The linear range of chlorogenic acid was 0.26-0.79 μg for(r=0.999 9). The limits of quantitation and detection were 0.26,0.12 μg, respectively. RSDs of precision,stability and reproducibility tests were lower than 1.0%. The recoveries were 96.11%-101.96%(RSD=1.98%,n=9). CONCLUSIONS:Established standard can be used for quality control of Siwei jiangmei tablets.