Preliminary experience and mid-term follow up results of patients after transcatheter aortic valve replacement
10.3969/j.issn.1004-8812.2018.03.003
- VernacularTitle:经导管主动脉瓣置换术治疗重度主动脉瓣狭窄的初步经验及中期随访结果
- Author:
Bin WANG
1
;
Mao-Long SU
;
Ke-Ke LAI
;
Feng QIU
;
Guo-Sheng XIAO
;
Tao YE
;
Hong-Mei WEN
;
Jian WANG
;
Yan WANG
Author Information
1. 厦门大学附属心血管病医院心内科
- Keywords:
Transcatheter aortic valve replacement;
Aortic valve stenosis;
Heart failure
- From:
Chinese Journal of Interventional Cardiology
2018;26(3):138-143
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the preliminary experience and mid-term outcome of transcatheter aortic valve replacement(TAVR)in patients with calcifi ed severe aortic stenosis.Methods From December 2014 to February 2016, 10 TAVR cases were admitted in the Cardiovascular Hospital, Xiamen University. The baseline characteristics, echocardiography parameters and clinical follow-up data were analyzed. Results All cases were complicated with impaired heart function(NYHAⅢ in 4 cases, NYHA Ⅳ in 6 cases). The mean age was (75.1±6.2) years and 4(4/10) of them were men. The mean logistic EuroSCORE was (27.2±23.6) % and the mean society of thoracic surgery (STS) mortality score was (9.1±4.8) %. Five cases had bicuspid aortic valve. TAVR was successfully performed in all 10 patients, and valve-in-valve implantation was done in 1 (10%) case. Immediately after procedure, the peak trans-aortic valve pressure gradient decreases from (85.9±22.7) mmHg to (23.2±5.4) mmHg. One case had marginal moderate periprosthetic leak and one case received stent implantation for femoral artery complication during the procedure. During hospitalization, 1 case had blood transfusion for gastrointestinal bleeding and permanent pacemakers were implanted in 2 (2/10) cases. The survival rate was 10/10 at 30 days after TAVR. One case with end-stage renal disease died for gastrointestinal bleeding 36 days after TAVR. For the other 9 patients, 12 months echocardiography data showed that the peak and mean trans-aortic valve gradient was (20.0±5.2) mmHg and (10.6±3.1) mmHg respectively. The lef t ventricular diastolic diameter(LVDD)decreased[(56.5±9.4)mm vs.(51.8±7.6)mm,P=0.035] and left ventricular ejection fraction(LVEF)increased significantly[(46.9±22.2)% vs.(63.7±9.4)%, P=0.029].To date,median follow-up period was(22.0±4.8)month.Clinical symptoms improved in all the 9 cases. The patient with periprosthetic leak had record of hospitalization for several times due to heart failure. Conclusions From the initial TAVR experience of our hospital, TAVR can be done safely and smoothly after strictly TAVR candidate cases selection.