Determination of aconitine in biological human sample by UPLC-MS/MS
10.13618/j.issn.1001-5728.2018.01.017
- VernacularTitle:超高效液相色谱-质谱联用法测定生物检材中乌头碱
- Author:
Yuan ZHANG
1
;
Bo CHEN
;
Meiling ZHANG
;
Haiqin ZHAO
;
Lin LIN
;
Dan LIN
;
Xianqin WANG
Author Information
1. 温州医科大学司法鉴定中心法医毒物实验室
- Keywords:
forensic toxicological analysis;
UPLC-MS/MS;
aconitine;
biological sample
- From:
Chinese Journal of Forensic Medicine
2018;33(1):68-70
- CountryChina
- Language:Chinese
-
Abstract:
Objective To develop a simple and fast UPLC-MS/MS method for determination of aconitine in biological human sample. Methods The biological human sample was treated by acetonitrile precipitation, and then analyzed on a UPLC C18(2.1mm×50mm, 1.7μm)column. The mobile phase consisted of acetonitrile-0.1% formic acid with gradient elution, at a flow rate of 0.4 mL/min, at 40℃. UPLC-MS/MS was performed in ESI source with MRM mode for quantification. Results The linear range of the concentration were 0.5~500ng/mL in blood and 1~1000ng/mL for aconitine in blood for aconitine (r>0.995). The relative recoveries of aconitine were in the range of 91.3%~110.2%, and the extraction recoveries were in the range of 72.8%~83.5%. The RSDs of intra-days and inter-day were both less than 14%. Conclusion The method is a simple, fast and could be used for determination of aconitine in biological human sample.