Role of the optic disc parameters and retinal thickness measured by frequency domain OCT in early glaucoma diagnosis
10.13389/j.cnki.rao.2018.0105
- VernacularTitle:频域光学相干断层扫描(OCT)测量视盘参数及视网膜厚度在早期青光眼诊断中的作用
- Author:
Shang-Li JIN
1
;
Jin ZENG
;
Zhi-Hui CHEN
;
Qiao-Lian YIN
;
Shu-Mei XIANG
Author Information
1. 东莞市常平医院眼科
- Keywords:
frequency domain OCT;
optic disc;
retinal nerve fiber thickness;
glaucoma
- From:
Recent Advances in Ophthalmology
2018;38(5):452-456
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the roles of frequency domain OCT in measuring the retinal thickness around the optic disc and optic disc parameters in early glaucoma diagnosis.Methods The optic disc parameters and retinal nerve fiber layer (RNFL) thickness in the 40 healthy volunteers (control group) and 85 cases of primary open angle glaucoma (POAG),including 36 patients as the early glaucoma subgroup and 49 patients as the glaucoma evolutum subgroup,were measured by frequency domain OCT.Then,the correlation analysis of RNFL thickness,optic disc parameters and the mean deviation (MD) of visual field in each group was performed,and the area under the curve was used to evaluate the diagnostic efficiency of RNFL thickness around the optic disc and optic disc parameters in the diagnosis of glaucoma.Results The RNFL thickness and the complete cycle mean RNFL thickness in the temporal,upper,nasal and inferior quadrant in the glaucoma patients were significantly lower than those in the controls (all P < 0.05),and the above indexes in the glaucoma evolutum subgroup were significantly decreased compared with those in the early glaucoma subgroup (all P < 0.05).There were statistically significant differences in the optic disc parameters between the groups except the optic disc area (all P < 0.05).Pearson correlation analysis showed the RNFL thickness and the complete cycle mean RNFL thickness in the temporal,upper and inferior quadrant were negatively correlated with the MD in the glaucoma patients (all P < 0.05),and the parameter of optic cup volume and cup/disc area ratio were positively correlated with the MD (both P < 0.05),and the rim area,rim volume and disc volume were negatively correlated with MD (all P < 0.05).The ROC curve analysis showed that the largest area under the curve of RNFL thickness in the inferior quadrant of the optic disc region was 0.886,and the specificity and sensitivity was 0.775 and 0.924,respectively.Moreover,the area under the curve of the optic cup/optic disc area was the largest,with sensitivity and specificity of 0.741 and 0.815,respectively.Conelusion OCT for measuring optic disc structure and RNFL thickness can be used for early diagnosis of glaucoma,and it has a high sensitivity and specificity.