Clinical observation of femtosecond laser capsulorhexis with toric intraocular lens implantation
10.13389/j.cnki.rao.2018.0059
- VernacularTitle:飞秒激光撕囊复曲面人工晶状体植入的临床观察
- Author:
Li XU
1
;
Yong WANG
;
Xian-Yi BAO
;
Yan-Li ZHOU
;
Dan-Min CAO
;
Han LI
Author Information
1. 武汉爱尔眼科医院
- Keywords:
femtosecond laser;
Toric IOL;
astigmatism;
stability;
decentration
- From:
Recent Advances in Ophthalmology
2018;38(3):255-258
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the clinical effect of femtosecond laser assisted cataract surgery with Toric IOL implantation on correcting astigmatism and IOL rotating stability.Methods A prospective,nonrandomized,controlled study was conducted in 68 patients (82 eyes) diagnosed as age-related cataract with more than 1.0 diopter (D) regular astigmatism,including 41 eyes undergoing Toric IOL implantation with femtosecond laser assisted cataract surgery,and the other eyes receiving Toric IOL with phacoemulsification.And observation was performed for the uncorrected visual acuity (UCVA) before operation and 6 months after operation,preoperative corneal astigmatism,anticipated and postoperative residual astigmatism 6 months after operation.Then,comparison was performed for the degree of Toric lens axis rotation,as well as the horizontal and vertical movement of the IOL and the degree of vertical deflection in the capsule at 1,3,and 6 months after operation.Results In the observation group,preoperative UCVA (logMAR),preoperative corneal astigmatism,postoperative BCVA and the residual astigmatism at 6 months after operation was 1.03 ± 0.32,(2.09 ± 0.73) D,0.13 ± 0.11 and (0.33 ± 0.27) D,respectively,while the corresponding data in the control group was 0.92 ± 0.40,(1.69 ± 0.64) D,0.13 ± 0.09,(0.26 ± 0.22) D;the postoperative visual acuity in both groups was significantly improved,and residual astigmatism was significantly decreased at 6 months after operation (all P < 0.001).There was no significant difference in Toric lens axis after femtosecond laser assisted surgery and phacoemulsification at 1 month,3 months,6 months after operation (all P > 0.05),but the differences in the IOL movement in horizontal and vertical direction were statistically significant at the different time-points (all P < 0.05),and there was significant differences in the degree of vertical deflection (all P < 0.05).Conclusion Both femtosecond laser assisted cataract surgery and phacoemulsification combined with Toric IOL can achieve a better stability and predictability.