Evaluation of the effect of metronome in the new nurse training of cardiopulmonary resuscitation based on Solomon four-group design
10.3760/cma.j.issn.1672-7088.2018.11.015
- VernacularTitle:基于所罗门四组设计的"节拍器"在新护士心肺复苏术培训中的效果评价
- Author:
Chunlan LIU
1
;
Xueping LI
;
Zhen ZHANG
;
Jing'ai HUANG
;
Weili WANG
;
Jie SONG
;
Yanxun LIU
Author Information
1. 山东大学齐鲁医院护理部
- Keywords:
Metronome;
Cardiopulmonary resuscitation;
Solomon four-group design;
New entry nurses;
Standardized training
- From:
Chinese Journal of Practical Nursing
2018;34(11):866-870
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the effect of using"metronome"to guide chest compression in the new nurse training of cardiopulmonary resuscitation(CPR). Methods From 2015 to 2016,385 new nurses were enrolled and randomly by random number table divided into four groups based on Solomon four-group design:control group 1(96 nurses),sudy group 1(89 nurses),control group 2(104 nurses) and study group 2(96 nurses),Control group 1 and control group 2 accepted normal training plus "chest compressions operation formula" training,study group 1 and study group 2 got "metronome" guiding based on the frequency training.Control group 1 and study group 1 took a baseline test before the training started,while control group 2 and study group 2 didn't.Four groups took part in an operational test after the seven days of training. Results There was no statistical difference between the baseline test scores of control group 1 and study group 1(P>0.05).After the training,the score of study group 1 was 93.4±3.5, which was significantly higher than 91.6 ± 4.7 of control group 1(t=-2.870, P<0.01).Through covariance analysis,after removing the impact of the baseline test score,the score of study group was statistically significant higher than that of control group 1 (F=7.33, P=0.007).Furthermore,there was no statistically significant interaction between the baseline test score and training method (P>0.05).Meanwhile,after training,study group 2 scores was 93.5±3.5,which was statistically higher than 92.1±4.0 of control group 2(t=2.670,P=0.008).Control group 1 were combined with control 2 to form control group,as well as study group 1 with study group 2 to form study group.A comparison between these two new groups indicates that the new study group surpasses the new control group with lower error frequencies in the position,depth and frequency of external cardiac compression (t=4.701 8, 12.488 9, 11.993 9, P<0.05).In addition,the study group also showed a better performance, when taking into consideration of the region and skills of compression and the observation of complexion,while there was no statistical difference between the error frequencies in these three aspects of these two new groups(P>0.05). Conclusions In the CPR training of new nurses,using a 100 times/min"metronome"can help new nurses grasp the accurate compression rates and depth, improve the overall quality of this procedure,making it a simple and effective training method,which is worthy of popularization.