Application of dual-source CT spectrum energy curve and iodine quantification in determination of differentiation degree of clear cell renal carcinoma
10.3969/j.issn.1002-1671.2018.02.018
- VernacularTitle:双源CT能谱曲线及碘含量测定评估肾透明细胞癌分化程度的应用
- Author:
Yue CUI
1
;
Hua HE
;
Wenling LI
;
Yulin GUO
Author Information
1. 宁夏医科大学
- Keywords:
clear cell renal carcinoma;
iodine quantification;
differentiation degree;
computed tomography
- From:
Journal of Practical Radiology
2018;34(2):234-237
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the value of dual-source CT spectrum energy curve and iodine quantification in determining the degree of differentiation of clear cell renal carcinoma(ccRCC).Methods The radiographic data of 38 cases with pathologically confirmed ccRCC were analyzed retrospectively.All patients underwent dual-source CT,cortical phase and nephrographic phase dual energy scan,including 22 well-moderated differentiated(gradeⅠ,gradeⅡ)and 16 poorly differentiated neoplasms(gradeⅢ,gradeⅣ).The slope of spectrum energy curve (40-70 keV,70-100 keV,100-140 keV)and the normalized iodine concentration (NIC)between the two grades were compared. Results In the spectrum energy curve 40-70 keV and 70-100 keV segment interval,the slope of spectrum of well-moderated differentiated group was higher than that of poorly differentiated group,the difference was statistically significant(P<0.05).In the 100-140 keV segment interval,the slope of spectrum of well-moderated differentiated group was higher than that of poorly differentiated group, but the difference was insignificant(P>0.05).The NIC of well-moderated differentiated group was significantly higher than that of poorly differentiated group(P<0.05).Conclusion The slope of spectrum energy curve and NIC are correlated with the differentiation degree of ccRCC.The slope of spectrum energy curve and iodine quantification of dual-source CT could be used as new methods for preoperative grading of ccRCC.