The 24 - hour pattern of intraocular pressure in suspected glaucoma patients
10.3980/j.issn.1672-5123.2018.5.37
- VernacularTitle:疑似青光眼患者24h眼压变化规律
- Author:
Shan-Shan LI
1
;
Feng-Shuang LI
;
Li-Yang JI
;
Ce ZHANG
;
Jing-Min LI
Author Information
1. 大连医科大学附属第二医院眼科
- Keywords:
24-hour intraocular pressure monitoring;
habitual position;
glaucoma;
Accupen tonometer
- From:
International Eye Science
2018;18(5):915-918
- CountryChina
- Language:Chinese
-
Abstract:
AIM: To analyze the value of 24 - hour intraocular pressure ( IOP) monitoring in suspected glaucoma patients. METHODS: Totally 48 suspected glaucoma (96 eyes) were selected for 24 - hour IOP monitoring by using Accupen tonometer (24 - 3000) and non - contact tonometer (NCT, CT-80A) from 9 30 to 7 30 next day (once in 2h). During 07 30 to 21 30, patients were measured in sitting position,while during 23 30 to 05 30 in both sitting and supine position. RESULTS:A morning peak of IOP was shown at 7 30 in traditional position by using two measures with 22.05士3 608mmHg of NCT and 19.79士4.147mmHg of Accupen tonometer. The peak IOP in habitual position appeared in 5 30 with 21.64士4.814mmHg. The lowest IOP occurred in both position at 21 30 with 15. 73士3. 649mmHg. Both positions showed IOP trend of going up at night and then declining in the morning. CONCLUSION: The peak IOP in suspected glaucoma occurs mostly at early morning. Supine IOP of sleeping time is higher than that of sitting position.