Air pressure cuff-assisted thrombolytic therapy in treating deep venous thrombosis of lower extremity:a comparison study of two kinds of air pressure cuff
10.3969/j.issn.1008-794X.2017.11.019
- VernacularTitle:下肢深静脉血栓溶栓治疗中两种气囊压力带辅助应用的对照研究
- Author:
Yan LI
1
;
Tingting CHEN
;
Yuanyuan YIN
;
Xiaomei LI
;
Janesya SUTEDJO
;
Boxiang ZHAO
;
Jianping GU
Author Information
1. 210006,南京医科大学附属南京医院(南京市第一医院)介入血管科
- Keywords:
lower limb deep venous thrombosis;
thrombolytic therapy;
superficial vein;
blood flow occlusion
- From:
Journal of Interventional Radiology
2017;26(11):1042-1045
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the optimal pressure range produced by two types of air pressure cuff in order to block superficial vein to assist thrombolytic therapy for deep venous thrombosis (DVT) of lower extremity,which can effectively dissolve the thrombus as well as improve the patient's comfort,and to provide useful basis for the implementation of individualized and standard nursing process.Methods A total of 80 patients with lower limb DVT were randomly and equally divided into the modified air pressure cuff group (study group,n=40) and the traditional standard sphygmomanometer cuff group (control group,n=40).Thrombolytic therapy by using continuous intravenous infusion of urokinase via the dorsalis pedis vein with infusion pump was performed in all patients of both groups.The daily dose of urokinase was the same.The pressure value to obstruct lower limb superficial venous blood flow,that was the airbag pressure value when the deep veins of lower limb became visualized on venography,was determined.Leg swelling fade-away rate,mean thrombus clearance rate and patient's comfort degree,etc.were calculated,and the results were compared between the two groups.Results In the study group,the pressure value to block superficial venous blood flow of lower limb was 65-75 mmHg with a mean of (70±5) mmHg;which in the control group was 60-85 mmHg with a mean of (70±10) mmHg.The Leg swelling fade-away rate,the mean thrombus clearance rate determined at different time points,and the patient's comfort degree of the study group were remarkably better than those of the control group (P<0.05).Conclusion Compared to the use of traditional standard sphygmomanometer cuff,the use of modified air pressure cuff to block the lower limb superficial venous blood flow can obtain better thrombolytic effect,meanwhile,the patients can get high comfort degree in the therapeutic process.