Color Doppler two-dimensional ultrasound combined with real-time ultrasonic shear wave elastography in breast cancer diagnosis
10.3760/cma.j.issn.1673-4181.2018.04.006
- VernacularTitle:彩色多普勒二维超声联合实时超声剪切波弹性成像用于乳腺癌诊断
- Author:
Shuxin CHEN
1
;
Zhihui HU
;
Ying HOU
;
Hong JIN
;
Jiefang SHI
;
Jie XUE
Author Information
1. 301700,天津武清区人民医院超声诊疗科
- Keywords:
Ultrasound diagnosis;
Breast cancer;
Ultrasound shear wave elastography
- From:
International Journal of Biomedical Engineering
2018;41(4):305-309
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the value of color Doppler two-dimensional ultrasound combined with real-time ultrasonic shear wave elastography (SWE) in the early diagnosis of breast cancer.Methods A total of 110 suspected breast tumor patients from October 2015 to April 2017 were selected as subjects.Comprehensive detailed examinations on the patients were conducted by routine two-dimensional ultrasound,color Doppler and SWE,and the lesion location,size,boundary,capsule,internal echo,blood flow,elastic value and other related data were recorded.The BI-RADS classification was conducted based on these data.Pathological diagnosis was used as the gold standard to compare the diagnostic effects of color Doppler two-dimensional ultrasound and the combination of color Doppler two-dimensional ultrasound and SWE.Results Of the 110 patients,78 were malignant and 32 were benign.The sensitivity of color Doppler two-dimensional ultrasound for breast cancer diagnosis was 83.3%,the specificity was 81.2%,and the accuracy was 82.7%.The sensitivity of color Doppler two-dimensional ultrasound combined with SWE for breast cancer diagnosis was 88.5%,the specificity was 90.6%,and the accuracy was 94.5%.Conclusion Color Doppler two-dimensional ultrasound combined with SWE can complement each other and improve the qualitative and quantitative diagnosis of early breast cancer.