Clinical study of locking-taper implants in patients treated for periodontitis.
- Author:
Hai Dong ZHANG
1
;
Li ZHANG
1
;
Dong SHI
1
;
Jie HAN
1
;
Xia YAN
1
;
Ye Si XIE
1
;
Huan Xin MENG
1
Author Information
1. Department of Peiriodontics, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
- Publication Type:Journal Article
- MeSH:
Aggressive Periodontitis/therapy*;
Chronic Periodontitis;
Dental Implants;
Dental Scaling;
Humans;
Periodontal Index;
Tooth Loss;
Treatment Outcome
- From:
Journal of Peking University(Health Sciences)
2018;50(2):300-307
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To evaluate the survival rate and peri-implant clinical parameters of Locking-Taper implants in patients having lost their teeth due to non-periodontitis (NP) reasons, chronic periodontitis (CP) and aggressive periodontitis (AgP).
METHODS:In the study, 145 subjects were installed with 315 Bicon Locking-Taper implants and followed up for 1-5 years. The subjects and implants were classified into three groups, tooth loss by NP, CP and AgP. NP included 44 subjects with 100 implants, CP 70 subjects with 132 implants and AgP 31 subjects with 83 implants. Periodontal parameters before subgingival scaling and root planning (T0), at the end of active periodontal therapy (T1) and at the time of last recall (T2) were recorded. Right after the installation of final restoration and at the time of last recall (T2), peri-implant probing parameters were recorded.
RESULTS:After active periodontal therapy, mean probing depth (PD) in CP and AgP were reduced from 4.05 mm, 5.20 mm at T0 to 3.07 mm, 2.96 mm at T1 (P<0.001, P<0.001), (PD≥6 mm)% were reduced from 33.2%, 58.5% at T0 to 14.4%, 10.5% at T1 (P<0.001, P<0.001). The periodontal parameters remained stable at T2 compared with T1 (P>0.05). Cumulative survival rates of implants in NP, CP and AgP were 100%, 97.6% and 100% for 1-5 years' follow-ups with no statistical significance found. At T2, mean implant PD was 2.78 mm, 2.96 mm and 2.97 mm in NP, CP and AgP, with NP significantly lower than the other two groups (P=0.006, P=0.01). The percentage of implant sites with PD≥6 mm was 3.7% in CP and 4.8% in AgP, both significantly higher than NP (P=0.003, P<0.001). 8.4% implant sites showed at least 2 mm deeper than those at prosthesis installation were found in CP group, significantly higher than NP (4.3%, P=0.003).
CONCLUSION:Periodontal conditions of patients having lost their teeth for chronic and aggressive periodontitis were significantly improved after active periodontal therapy and remained stable during 1-5 years. Short-term survival rates of Locking-Taper implants in patients treated for CP and AgP was no less than those who lost their teeth for non-periodontitis reasons. More sites with increasing peri-implant probing depth were found in CP and AgP patients, compared with NP.