Determination of poly-mannugluronic acid in urine by electrophoresis
- VernacularTitle:电泳法检测尿液中海洋硫酸多糖聚甘古酯原型物
- Author:
Wei XIA
;
Gang DENG
;
Meiyu GENG
;
- Publication Type:Journal Article
- Keywords:
poly mannuguluronic acid;
electrophoresis;
polysaccharide
- From:
Chinese Journal of Marine Drugs
1994;0(01):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To establish a cellulose acetate membrane electrophoretic method for separating the exogenous sulfated poly mannuguluronicate(911) from glycosaminoglycans.Methods 911 both in urine and ultrafiltrated urine were extracted with cetylpyridinium chloride (CPC), and then separated by two step electrophoretic method with two different buffer solutions. Results The results indicated that 911 was thoroughly separated from endogenous CSC and DS with its average recovery in urine approximately at 70%. Furthermore, the lowest sensitivity for determination of 911 in aquatic solution was 100 ?g?L -1 , whereas that in urine 250 ?g?L -1 and in ultrafiltrated urine 500 ?g?L -1 . And most importantly 911 in rat's urine was detectable after it's oral administration at dose of 200mg?kg -1 . Conclusions It is the first time for us to conduct the existence of 911 in urine by two step electrophoretic method with two different buffer solutions, suggestive of the feasibility to determine 911 in urine even following it's oral administration.