DETECTING THE HAEMODYNAMIC EFFECTS OF PREMATURE SYSTOLES WITH IMPEDANCE CARDIOGRAMS
- VernacularTitle:过早搏动的血流动力学改变——阻抗法检测
- Author:
Yongan LI
;
Yunzhen CHEN
;
Rongzhong WANG
;
Chuanping ZHANG
;
- Publication Type:Journal Article
- Keywords:
Premature systoles;
Haemodynamic;
Impedance
- From:
Journal of Chongqing Medical University
1986;0(02):-
- CountryChina
- Language:Chinese
-
Abstract:
0.05). The average SV of premature systoles is 35% of sinus beats. Premature systoles less than 5 beats/min may cause and average drop of 5% of cardiac output (CO), While the premature systoles increased to 10-20 beats/min, the CO would be dropped further of 10-19%. there Was a high linear correlation between sr of all premature systoles and the coupling interval premature systoles (p