Injuries of anterior glenoid labrum:evaluation with MR arthrography
- VernacularTitle:肩关节MR造影对肩关节前方盂唇病变的诊断价值
- Author:
Zhuo-Zhao ZHENG
;
Guo-Qing CUI
;
Jia-Dong FAN
;
Jing-Xia XIE
;
- Publication Type:Journal Article
- Keywords:
Shoulderdislocation;
Arthrography;
Magneticresonanceimaging
- From:
Chinese Journal of Radiology
2001;0(09):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To determine the diagnostic value of shoulder MR arthrography in revealing the injuries of anterior glenoid labrum,and to compare MR arthrography with arm in neutral position with MR arthrography with arm in abduction and external rotation(ABER)position.Methods MR arthrography of the shoulder,including additional oblique axial sequences with the patient in the ABER position,was performed in 44 patients.The injuries of anterior glenoid labrum of these patients were retrospectively evaluated.The result was compared with that of arthroscopy.Results For displaying the abnormalities of anterior glenoid labrum,the sensitivity,specificity,and accuracy of axial MR images with arm in neutral position were 79.3%(23/29),100%(15/15),and 86.4%(38/44),respectively.While the results of ABER position oblique axial images were 93.1%(27/29),100%(15/15),and 95.5%(42/44), respectively.The difference of sensitivity between axial and ABER-position scans was statistically significant (P