A comparative study of PaCO_2 and PetCO_2 under different respiration patterns during artificial valve replacement
- VernacularTitle:瓣膜置换术患者不同呼吸状态下PetCO_2与PaCO_2关系研究
- Author:
Fujun ZHANG
;
Meiying XU
;
Jianer DU
;
- Publication Type:Journal Article
- Keywords:
heart valve prosthesis implantation;
respiration;
ventilators,mechanical;
blood gas analysis
- From:
Academic Journal of Second Military Medical University
2000;0(08):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the relationship between PaCO 2 and PetCO 2 while the respiration pattern changed from spontaneous to mechanical ventilation during artificial valve replacement. Methods:The changes of PaCO 2,PetCO 2,CO,MAP,PAP,CVP,PAWP,SVR,PVR and V D/V T,alv from spontaneous respiration to mechanical ventilation were observed pre and post general anesthesia in 22 patients undergoing artificial valve replacement. Results:Compared with spontaneous respiration before general anesthesia induction, the differences between PaCO 2 and PetCO 2,CVP,V D/V T,alv ratio were significantly increased( P