Two cases of extracorporeal membrane oxygenation as a bridge to heart transplantation
- VernacularTitle:心脏移植前采用体外膜肺氧合循环支持过渡二例
- Author:
Fei-Long HEI
;
Shi-Gang WANG
;
Kuno YU
;
- Publication Type:Journal Article
- Keywords:
Heart-assist devices;
Heart failure;
congestive;
Heart transplantation
- From:
Chinese Journal of Organ Transplantation
2005;0(07):-
- CountryChina
- Language:Chinese
-
Abstract:
160 s and core temperature was 36-37℃.Blood ga- ses,platelets,plasma free hemoglobin and coagulation factors were measured during ECMO support. The blood supply was monitored in the limbs cannulated with the femoral artery cannula.Results Two patients were successfully treated with ECMO without major complications.The circulatory and respiratory function of the patients was stable.The chest X-ray showed a no clouding of lungs and he- patic function was greatly improved in case 2 who underwent a successful heart transplantation follo- wing mechanical cardiocirculatory support as a bridge,Two patients received ECMO support for 5 and 3 days respectively.Both patients recovered well.No any severe acute rejection occurred and heart func- tion was NYHAⅠ.Conclusion When candidates suffered acute cardiogenic shock,ECMO can provide safe and effective mechanical circulatory support as a bridge to heart transplantation.