Treatment of lumbar isthmic spondylolisthesis using titanium-coated interbody fusion system
- VernacularTitle:解剖型表面钛涂层椎间融合系统治疗椎弓崩裂性腰椎滑脱
- Author:
Ya-Feng ZHANG
;
Hui-Lin YANG
;
Tian-Si TANG
;
Yong SHI
;
- Publication Type:Journal Article
- Keywords:
Lumbar vertebrae;
Dislocations;
Internal fixators;
Spinal fusion
- From:
Chinese Journal of Trauma
1993;0(06):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the clinical outcomes of titanium-coated interbody fusion system in treating lumbar isthmic spondylolisthesis.Methods A retrospective study was made in 22 cases with lumbar isthmic spondylolisthesis including 15 with degree I spondylolisthesis and seven with degree II spondylolisthesis treated by posterior lumbar interbody fusion using titanium-coated fusion cages from June 2002 to December 2003 in our hospital.There were six males and 16 females,with age range of 41-68 years(mean 52.5 years).In all cases,double cages were implanted with additional posterolateral bone graft,supplemented with pedicle screw systems.The average preoperative and postoperative disc space height,foraminal height,segmental and lumbar lordosis,spondylolisthesis and domain of sagittal rotation on flexion-extension radiographs were measured and fusion state observed.The Oswestry disability index (ODI)was used to evaluate the clinical outcome.Results The fusion rate was 95.4%.There was significant recovery of disc space height,foraminal height and domain of sagittal rotation.ODI decreased significantly.Conclusion The anatomic titanium-coated fusion system is effective and safe in treatment of lumbar isthmic spondylolisthesis because it has advantages in restoring sagittal alignment and keeping bony endplate intact.