Research on dynamic contrast-enhanced MR quantitative analysis of pancreatic cancer at 3.0T MR
10.3969/j.issn.1002-1671.2014.11.015
- VernacularTitle:3.0T 磁共振动态增强扫描定量分析在胰腺癌中的应用
- Author:
Na LI
;
Jing REN
;
Huijia LIU
;
Weihuan HOU
;
Qi PAN
;
Zhenhua ZHANG
;
Juntao LU
;
Yi HUAN
- Publication Type:Journal Article
- Keywords:
pancreatic cancer;
magnetic resonance imaging;
dynamic contrast-enhanced
- From:
Journal of Practical Radiology
2014;(11):1835-1838
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the value of dynamic contrast-enhanced quantitative parameters of pancreatic cancer at 3.0T MR.Methods 27 patients with pathologically proved pancreatic cancers were underwent DCE-MR at a 3.0 T scanner.AToft with Vp model was used to quantify K trans ,k ep ,Ve and Vp in the pancreatic cancer and normal pancreatic tissues.All parameters among different tissues were analyzed and compared by SPSS1 7.0.Results The K trans 、k ep 、Ve 、Vp values of pancreatic cancer were(0.303± 0.321)min,(1.387±1.486)min,(25.07±10.98)%and(3.420±4.692)% respectively ,while those values of normal pancreatic tis-sue were (1.235±0.777)min,(9.277 ± 7.996 )min,(1 7.89 ± 8.882 )%,and(7.1 96 ± 6.704)%,respectively.The differences be-tween the four parameters of pancreatic cancer and normal pancreatic tissue were statistically significant(F =33.188,25.414,6.984, 5.78,P <0.05).Conclusion Quantitative parameters of DCE-MRI accurately reflect changes in tumor blood perfusion and microcir-culation,they may be helpful to differentiate the atypical lesion.