The value of automated breast volume scanning, combined with virtual touch tissue imaging quantification in the differential diagnosis of benign and malignant breast lesion
10.3877/cma.j.issn.1672-6448.2017.07.008
- VernacularTitle:自动乳腺全容积成像联合声触诊组织成像量化技术在鉴别乳腺良恶性肿块中的价值
- Author:
Luoxi ZHU
1
;
Pintong HUANG
;
Lingyun BAO
;
Yanjuan TAN
;
Xiaojing XU
;
Lifang YU
Author Information
1. 浙江大学医学院附属第二医院超声科
- Keywords:
Automated breast volume scanning;
Virtual touch tissue imaging quantification;
Breast diseases
- From:
Chinese Journal of Medical Ultrasound (Electronic Edition)
2017;14(7):519-525
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the value of the automated breast volume scanning (ABVS) combined with virtual touch tissue imaging quantification (VTIQ) in the differential diagnosis of benign and malignant breast lesion.Methods Five hundred and seven patients with a total of 675 breast nodules were detected using ABVS and VTIQ technique.Of them,coronal plane imaging,SWVmax,SWVmin,and SWVmean (in m/s) for each nodule was acquired three days before operation or core needle biopsy.According to pathological results,the receiver operating characteristic (ROC) curve analysis was performed to evaluate the utility of the ABVS alone (retraction phenomenon on coronal plane),VTIQ alone and their combination in the diagnosis of breast lesions.Results Among all nodules,504 lesions were benign,and 171 were malignant.The rate of retraction phenomenon on coronal plane in malignant lesions was significantly higher than that in benign lesions (x2=279.89,P < 0.001).The value of SWVmax,SWVmin,SWVmean (6.79± 1.71 m/s,5.03 ± 1.24 m/s,5.74± 1.36 m/s) in malignant nodules were higher than that of benign nodules [(3.41 ±1.51) m/s,(2.46± 0.87) m/s,(2.65 ± 1.23) m/s],the differences were statistically significant (t=32.43,33.85,26.77,all P < 0.001).The AUC of malignant nodules for SWV (maximum,minimum,and average) were 0.922,0.934 and 0.937,respectively.With cut-off value of 4.045 m/s,SWVmean showed the best diagnostic performance.The sensitivity,specificity and accuracy of the retraction phenomenon on coronal plane,SWVmean and their combination in diagnosing malignant breast lesion were (39.65%,94.39%,95.78%),(97.50%,94.39%,95.53%) and (82.84%,93.51%,94.25%),respectively.And the SWVmean showed significant higher sensitivity than that of retraction phenomenon.The diagnostic capacity significantly improved when the two approaches were combined.Conclusion Both the retraction phenomenon on coronal plane and VTIQ had high diagnostic value,combining the two methods can improve the differential diagnosis ability for breast lesions.