Relationship between Evoked Auditory Steady-state Responses and Pure Tone Audiometry in Children with Different Levels of Hearing Loss
10.3969/j.issn.1006-7299.2017.06.009
- VernacularTitle:不同程度感音神经性听力损失儿童的Chirp-ASSR测试结果分析
- Author:
Chuling LI
1
;
Shujuan TAN
;
Xianglin LUO
;
Yuanming WANG
;
Baozhu YIN
;
Renzhong LUO
Author Information
1. 东莞市妇幼保健院、东莞市妇女儿童医院耳鼻咽喉-头颈外科 东莞523003
- Keywords:
Auditory steady-state responses;
Chirp;
Pure tone audiometry
- From:
Journal of Audiology and Speech Pathology
2017;25(6):591-594
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the clinical significance of Chirp-ASSR and the characteristics of hearing loss patients by ASSR(auditory steady-state responses) under Chirp stimulation.Methods A total of 136 hearing loss children (5~10 years old) with 272 ears were distributed into four groups based on 500 Hz,1 000 Hz,2 000 Hz and 4 000 Hz auditory threshold arithmetic average:20~dB HL,40~dB HL,60~dB HL,and≥80 dB HL groups.To compare the correlation of the PTA and Chirp-ASSR in different frequencies domain through SPSS statistics 19.0 software,the data were used T-test and Pearson analysis.Results ①The group(≥80 dB HL) achieved a statistically significant higher reaction threshold than pure tone threshold.②The correlation index γ'of PTA and Chirp-ASSR showed a decline along with the hearing loss increase;It increased along with the test frequency,there was a significant difference between 500 Hz and 4 000 Hz(P<0.05).Conclusion Chirp-ASSR is a frequency-specific electrophysiological test method,it could reflect the truthful listening ability,especially in mild,moderate,and severe hearing loss children.