The application value of cone beam CT in the diagnosis of sialolithiasis
10.3969/j.issn.1001-3733.2017.05.013
- VernacularTitle:锥形束CT在涎石症诊断中的应用价值
- Author:
Rui SUN
1
;
Hengwen CHEN
;
Wei AN
;
Wen'ge CHEN
;
Zhijiang GAO
Author Information
1. 山西省人民医院口腔颌面外科
- Keywords:
Sialolithiasis;
Cone beam computed tomography(CBCT);
Sensitivity;
Negative predictive value
- From:
Journal of Practical Stomatology
2017;33(5):630-634
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To find the better imaging method for the diagnosis of sialolithiasis by comparing the 3 different imaging methods.Methods:32 cases of salivary calculus were examined by sonography,X-ray and cone beam computed tomography(CBCT),the sensitivity,specificity,positive predictive value,negative predictive value were compared among the 3 methods.Results:The sensitivity and negative predictive value of cone beam computed tomography(95.8% and 80%) was significantly higher than those of sonography(83.3%,50.0%) and X-ray(58.3%,20%)(P < 0.05).Of three imaging methods there was no statistical difference in specificity and positive predictive value.Conclusion:CBCT is more sensitive than sonography or X-ray in the diagnosis of sialolithiasis.