Early-and mid-term clinical efficacy of endovascular repair for Stanford B aortic dissection
10.3969/j.issn.1006-5725.2017.23.023
- VernacularTitle:Stanford B型主动脉夹层覆膜支架腔内修复术近中期的疗效
- Author:
Xiangyun MA
1
;
Genshang ZHAO
Author Information
1. 450014,郑州大学第二附属医院心血管外科
- Keywords:
covered stent;
Stanford and B aortic dissection;
thoracic endovascular aortic/aneurysm re-pair
- From:
The Journal of Practical Medicine
2017;33(23):3942-3945
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the early and mid-term clinical efficacy and safety of endovascular re-pair for Stanford B aortic dissection. Methods Fifty-seven patients with Stanford B aortic dissection from July 2012 to July 2016 were selected.Based on the preoperative CTA image data,the appropriate stent grafts were cho-sen,and then endovascular graft exclusion was performed under the DSA perspective. The complications and mor-tality 3,6,12 and 24 months after the operation were observed,and the clinical features,curative effect and follow-up results were analyzed.Results The success rate of operation reached 100% and the average length of hospital-ization was 11 d.There were 1 case of postoperative 3 d leakage,1 postoperative 7 d death and 1 of recurrent dis-section 13 months later.Postoperative follow-up of 3 to 24 months showed that there were no postoperative paraple-gia,no dislocated and regressive stents and no occurrence of transposition and breakage of stent. Conclusions Covered stent in the treatment of Stanford B aortic dissection has the advantages of less trauma,safety,rapid recov-ery,simple operation,high success rate,less complications,definite curative effect in early-and middle-term and low fatality rate.