A comparative study of using Brix meter versus ultrasonic monitoring of gastric residual volume in patients with enteral nutrition
10.3760/cma.j.issn.0578-1426.2017.12.010
- VernacularTitle:白利度计与超声测量肠内营养患者胃残余量的对比研究
- Author:
Yu DING
1
;
Gangshi WANG
;
Ying ZHANG
;
Huiru HOU
Author Information
1. 解放军总医院南楼消化科
- Keywords:
Ultrasonography;
Enteral nutrition;
Gastric residual volume;
Brix value
- From:
Chinese Journal of Internal Medicine
2017;56(12):940-942
- CountryChina
- Language:Chinese
-
Abstract:
To investigate the accuracy and feasibility of Brix value on monitoring gastric residual volume (GRV) in patients with enteral nutrition. Fifty patients with enteral nutrition via nasogastric tube were enrolled. The GRV was measured by both ultrasonography and Brix value. The results were compared according to the methods. The Pearson correlation coefficients showed that GRV measured by these two ways was positively correlated (r=0.986, P<0.05). Moreover paired sample t-test showed that the discrepancy was not statistically significant (P>0.05) between different measurements. The consistency was analyzed by Bland-Altman graph, showing that the two measurements were consistent. Brix value is recommended to measure GRV due to its convenience and easy operation.