Clinical applications of conformity index and homogeneity index
10.3760/cma.j.issn.0254-5098.2017.09.016
- VernacularTitle:适形指数和均匀性指数的临床应用
- Author:
Yan SHAO
1
;
Hao WANG
;
Hua CHEN
;
Hengle GU
;
Zhiyong XU
Author Information
1. 210000,上海交通大学附属胸科医院放疗科
- Keywords:
Radiotherapy;
Conformity index;
Homogeneity index
- From:
Chinese Journal of Radiological Medicine and Protection
2017;37(9):717-721
- CountryChina
- Language:Chinese
-
Abstract:
With the development of technology, several treatment plans can be got easily. There are many parameters related to the treatment in each plan and it is not only complex but also time-consuming to analyze them. So it is difficult for radiation oncologists to choose a plan. In order to solve the problem, a fast tool was developed integrating parameters such as conformity index and homogeneity index. This paper reviewed the type development, formula and features of conformity index and homogeneity index, in order to provide reference for users.