Shear bond strength and failure patterns according to the material of resin base in indirect racket bonding.
- Author:
Man Bae JEON
1
;
Hyeon Shik HWANG
;
Jong Chul KIM
Author Information
1. Department of Orthodontics, College of Dentistry, Chonnam National University, Korea.
- Publication Type:Original Article
- Keywords:
indirect bonding;
light-cured resin;
shear bond strength;
ARI
- MeSH:
Adhesives;
Incisor
- From:Korean Journal of Orthodontics
1998;28(2):277-284
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
The purpose of this study was to evaluate the propriety of making use of the light-cured resin base in indirect bracket bonding technique by study of shear bond strength and failure patterns according to the material of resin base. Metal brackets were bonded to the stone models of specimens involving bovine lower incisor with chemical-cured(Excel), light-cured(Light-Bond) and thermal-cured(Therma-Cure) resin. They were transferred to the specimens and bonded using sealant. The shear bond strength was tested on Instron. After bracket removal, the bracket base was examined and assessed with the adhesive remnant index(ARI). The results were as follows: 1. No significant differences in shear bond strength were found among the three groups (P>0.05). 2. No significant differences in Alts score were found among the three groups (P>0.05). The above results suggest that light-cured resin base in addition to chemical-cured and thermal-cured resin bases is useful in the indirect bonding technique.