A Case of High Jugular Bulb Associated with Conductive Hearing Loss.
- Author:
Yong Joo YOON
1
;
Yun Soo YANG
;
Sang Heon LEE
;
Seung Choul CHOI
Author Information
1. Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Chunbuk National University, Jeonju, Korea. yang2002@dreamwiz.com
- Publication Type:Case Report
- Keywords:
Hearing loss;
conductive;
High jugular bulb
- MeSH:
Hearing Loss;
Hearing Loss, Conductive*;
Incidence;
Incidental Findings;
Tympanic Membrane
- From:Korean Journal of Otolaryngology - Head and Neck Surgery
2002;45(12):1184-1187
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
A high jugular bulb is often discovered as an incidental finding that is asymptomatic. The incidence of high jugular bulb protruding into the level of oval window is rare. Conductive hearing loss in association with this anomaly may occur, but has been reported infrequently in the literature. We report one case of high jugular bulb and the associated conductive hearing loss. Mechanisms to explain the conductive hearing loss include contact of the jugular bulb with tympanic membrane, interference with the ossicular chain, and obstruction of the round and oval window niche. The operative findings, radiographic and audiometric data that support these mechanisms of couductive hearing loss are presented.