Brachial Plexus Injury as a Complication of Arthroscopic Bankart Repair: A Case Report.
10.4055/jkoa.2009.44.6.675
- Author:
Chong Kwan KIM
1
;
Chin Woo JIN
;
Sung Weon JUNG
;
Ji Hoon LEE
Author Information
1. Department of Orthopaedic Surgery, Masan Samsung Hospital, Sungkyunkwan University School of Medicine, Masan, Korea. can1204@naver.com
- Publication Type:Case Report
- Keywords:
Brachial plexus injury;
Arthroscopic bankart repair
- MeSH:
Arthroscopy;
Brachial Plexus;
Shoulder
- From:The Journal of the Korean Orthopaedic Association
2009;44(6):675-679
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
Shoulder arthroscopy is widely used through the development of arthroscopic technique and equipment but some complications have been reported that are related to the complexity of technique and the long duration time of operation. Brachial plexus injury, as a complication of arthroscopic Bankart repair, is rare, but remains a serious sequelae. We performed the neurorrhaphy and neurolysis of brachial plexus and showed relatively good functional outcome after 2 years.