Gold-immunochromatography assay for detection of Yersinia pestis F1 antigen
10.3760/cma.j.issn.1000-4955.2010.06.026
- VernacularTitle:胶体金免疫层析法检测鼠疫F1抗原的研究
- Author:
He-zhi, LIU
;
Xue-wei, BAI
;
Hai-feng, WANG
;
Le-le, HU
;
Song, ZHOU
;
Xiao-yan, YANG
;
Guo-yi, DU
;
Shun-lin, YANG
;
Xian-ming, SHI
;
Yu-gui, LI
- Publication Type:Journal Article
- Keywords:
Gold colloid;
Chromatography,thin layer;
Yersiniapestis;
Antigens
- From:Chinese Journal of Endemiology
2010;29(6):678-681
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the sensitivity and specificity of gold-immunochromatography assay (GICA) for detection of Yersiniapestis(Y. pestis ) F1 antigen. Methods Viscera organ(liver and spleen) specimens of 308 mice with virulent Y. pestis infection and 225 control specimens of rats(217 Spermophilus dauricus, 5 mice,3 guinea pigs) were detected by GICA dipstick with monoclonal antibody against plague F1 antigen (F1MAb).Meanwhile, micro-method of reverse indirect hemagglutination assay(RIHA) and bacteria culture were carried out for parallel testing. Results Bacteriological examination of 225 control specimens, and F1 antigen detected with GICA and RIHA were all negative. No cross-reaction with related Yersinia pseudotuberculosis at 1 x 108 cfu/ml level was found in GICA and RIHA. Detection sensitivity of Y. pestis by GICA and RIHA were 2.5 × 105 cfu/ml and 2.0 × 105 cfu/ml, respectively, and of F1 antigen were 1μg/L and 10 μg/L, respectively. Coincidence was 97.94% (522/533) between GICA and bacteriological test, Kappa = 0.959, and the difference was statistically insignificant(x2 = 0.36, P > 0.05); and 97.94%(522/533) between GICA and RIHA, Kappa = 0.959, with statistically significant difference in the positive detection rates(x2 = 9.09, P < 0.05). Out of the 308 infected mice, 284 were positive of plague bacterial cultured, In 284 samples with positive bacterial culture, there were 280 of positive detected by GICA for F1 antigen, positive rate of F1 antigen was 98.59%, higher than that by RIHA[the positive rate of 96.13%(522/533)], with statistically significant difference(x2 = 5.14, P < 0.05). Sensitivity of GICA was 98.59% (280/284), specificity was 97.19% (242/249), positive predictive value (PPV) was 97.56% (280/287),negative predictive value ( NPV ) was 98.37% (242/246), and Youden index was 0.9578. Conclusions GICA is sensitive and specific, fast and simple in detection of F1 antigen of the plague. It's a valuable detection technique for early and rapid diagnosis of plague.