Fibrin glue for sealing early bleb leak :a case report
10.3969/j.issn.1672-5123.2009.05.007
- VernacularTitle:纤维蛋白胶封闭早期滤过泡漏1例
- Author:
Ali Hassan ALASHWAL
;
Azhany YAAKUB
;
Raja Azmi Mohd NOOR
;
Liza Sharmini Ahmad TAJUDIN
- Publication Type:Journal Article
- Keywords:
fibrin glue;
bleb leak;
filtering surgery
- From:
International Eye Science
2009;9(5):831-832
- CountryChina
- Language:Chinese
-
Abstract:
A 63-year-old male presented with sudden diminution of vision, eye discomfort, redness and watering in his left eye. He had undergone glaucoma valve filtering surgery for refractive secondary glaucoma one week back. He also had a history of failed augmented trabeculectomy one year earlier in the same eye. Ocular examination showed best corrected visual acuity(BCVA) of 6/18 and there was a bleb leak, shallow anterior chamber and intraocular pression(IOP) of 6mmHg. Successful sealing of bleb leak was performed using fibrin glue resulted in deepening of anterior chamber with IOP of 13mmHg. This case demonstrates that, fibrin glue is an effective method for management of early filtering bleb leak.