Clinical evaluation of two different -incision phacoemulsifications
10.3980/j.issn.1672-5123.2016.11.09
- VernacularTitle:不同切口超声乳化联合 MI60型人工晶状体植入术对白内障患者视觉质量的影响
- Author:
Chen, ZHAO
;
Yu-Qun, ZHANG
;
Jie, CEN
;
Pei-Yan, HUA
- Publication Type:Journal Article
- Keywords:
intraocular lens;
cataract;
vision function
- From:
International Eye Science
2016;16(11):2019-2021
- CountryChina
- Language:Chinese
-
Abstract:
AIM:To study and compare the outcomes of coaxial 2. 2 mm phacoemulsiflcation with conventional coaxial 3 mm small-incision cataract surgery.
METHODS: A randomized prospective study was conducted on 100 patients with age - related cataract:coaxial 2. 2 mm micro - incision cataract surgery was performed in 50 cases (50 eyes), and coaxial 3 mm small incision cataract surgery was performed in 50 cases ( 50 eyes) . Statistical analysis was takenwith the data of the two groups. Visual acuity, VF and QOL were compared at intervals of 1wk and 3mo after surgery. In addition, surgically induced astigmatism ( SIA ) was analyzed. Statistic analysis was taken by Student's t-test and Chi-square test.
RESULTS:There was no significant difference on BCVA (t=-1. 366, -1. 688; P=0. 148, 0. 107) between these two groups. One week and 3mo after the surgery, SIA was (0. 46±0.29)D, (0. 43±0. 26)D in the 2. 2 group; and (1. 55±0. 59) D, (0. 89±0. 28) D, in 3. 0 group. The differences between these two groups were statistically significant ( t=-7. 348, -3. 788; P = 0. 000, 0. 000 ) There were no statistically significant differences on VF scores between two group, while it's got a better score in 2. 2 groups on vision adaptation. (t=-3. 348, P<0. 05).
CONCLUSION:Coaxial 2. 2mm micro-incision cataract surgery could significantly reduce SIA and obtain morestable status of VF and QOL. This suggests that the coaxial 2. 2 phacoemulsification surgery implanted AkreosMI60 intraocular lens could get earliervisual rehabilitation postoperation.