Clinical observation of one transscleral sutured fixation intraocular lens implanted in the capsular treating traumatic lens dislocation
10.3980/j.issn.1672-5123.2016.11.39
- VernacularTitle:人工晶状体囊袋内缝合固定治疗外伤性晶状体半脱位
- Author:
Gang, LIU
;
Feng, GAO
;
Xiang-Jun, DAI
;
Yue-Jun, LIU
;
Fang, LI
- Publication Type:Journal Article
- Keywords:
intraocular lens;
traumatic lens dislocation;
capsular bag
- From:
International Eye Science
2016;16(11):2130-2132
- CountryChina
- Language:Chinese
-
Abstract:
AIM: To evaluate the safety and efficacy of one transscleral sutured fixation intraocular lens implanted in the capsular treating traumatic lens dislocation.
METHODS: Twelve eyes with lens subluxation from 12 patients during Mar. 2013 to Mar. 2015 were reviewed. The stopping and chopping method combined with manual nuclear extraction was performed in extent of lens subluxation less than 1/2 quadrant and transscleral sutured fixation intraocular lens implanted in the capsular. Visual acuity, best - corrected visual acuity, intraocular pressure, corneal endothelial cell count and the position of IOL were observed and recorded.
RESULTS: All the surgeries were performed successfully. Patients were followed up for 6 - 12mo. During the follow-up period, the number of eyes for BCVA ≥0. 8, 0. 4 - 0. 6 and ≤0. 3 was 2, 7 and 3, respectively. It meant 66. 67% of the eyes showed BCVA in 0. 5-0. 6. Intraocular pressure and the position of all intraocular lens were normal. Effects of operation on corneal endothelial cells were slight. No complications took place in and after surgery.
CONCLUSION: Without implanting capsular tension ring ( CTR ) , we successfully use the intraocular lens ( IOL) single loop suture fixation in the capsular bag for the treatment of the patient with traumatic lens dislocation. It indicates that the pressure and place shift from the use of IOL avoided by this method without implantation of CTR. This method is safe and effective for the treatment of eyes with traumatic lens dislocation.