Clinical effects of coaxial 1 . 8 mm microincision phacoemulsification
10.3980/j.issn.1672-5123.2016.10.10
- VernacularTitle:同轴1.8mm微切口白内障超声乳化吸除术的临床研究
- Author:
Na, HUI
;
Lei, YU
;
Cong-Yi, WANG
;
Xin-Guang, YANG
- Publication Type:Journal Article
- Keywords:
microincision;
phacoemulsification;
average ultrasound energy;
effective phacoemulsification time;
endothelial cell loss percentage;
surgery induced astigmatism
- From:
International Eye Science
2016;16(10):1828-1831
- CountryChina
- Language:Chinese
-
Abstract:
AIM:To observe and compare clinical effects of coaxial 1. 8mm microincision phacoemulsification and 3. 2mm small incision phacoemulsification.
●METHODS:A total of 117 eyes of 85 patients with age-related cataract in our hospital were divided randomly into two groups:43 patients (59 eyes) in the coaxial 1. 8 mm microincision cataract surgery group ( C - MlCS ) , 42 patients (58 eyes) in the coaxial 3. 2 mm traditional small incision cataract surgery group (C-SlCS). A total of 117 eyes were received phacoemulsification with intraocular lens implantation. Uncorrected visual acuity was recorded preoperatively and postoperatively at 1, 7, 30 and 90d. The effective phacoemulsification time and average ultrasound energy were recorded in surgery. Corneal endothelial cell and corneal topography were recorded preoperatively and postoperatively at 90 d.
●RESULTS:Uncorrected visual acuity ( logMAR) was no overall statistical significance difference between C-MlCS group and C-SlCS group (P>0. 05), but was significant statistical difference in different time-point within both groups(P<0. 05). Uncorrected visual acuity in different time-point had nothing to do with corneal wound size in cataract surgery(P>0. 05). On the 1 day after surgery, uncorrected visual acuity was 0. 16±0. 11 in C-MlCS group and 0. 22±0. 18 in C-SlCS group(P<0. 05). AVE was (7. 00± 2.72)% in C-MlCS group and (6. 16±3. 16)% in C-SlCS group (P>0. 05). EPT was (3. 09±1. 61)s in C-MlCS group and (3. 20±1. 92)s in C-SlCS group (P>0. 05). At 90 d after surgery, corneal endothelial cell loss percentage was (5. 81±2. 28)% in C-MlCS group and (5. 69±2. 38)% in C-SlCS group (P>0.05), SlA was (0.35±0.11) Din C-MlCS group and (0. 61±0. 13) D in C-SlCS group (P<0. 05).
● CONCLUSION: Compared with coaxial 3. 2mm traditional small incision cataract surgery, 1. 8mm coaxial microincision cataract surgery can get earlier visual rehabilitation and significantly reduce SlA. The coaxial 1. 8mm microincision cataract surgery is safe, effective and deserves further clinical applications.