Diagnosis of Ebstein anomaly with conventional and transthoracic real-time three-dimensional echocardiography
10.3877/cma.j.issn.1672-6448.2015.04.008
- VernacularTitle:常规及实时三维超声心动图在成人Ebstein畸形诊断中的应用价值
- Author:
Yong, JIANG
;
Hao, WANG
;
Minjie, LU
;
Linyuan, WAN
;
Wugang, WANG
;
Minghui, ZHANG
;
Weichun, WU
;
Xin, SUN
- Publication Type:Journal Article
- Keywords:
Echocardiography,three-Dimensional;
Tricuspid valve;
Heart diseases
- From:
Chinese Journal of Medical Ultrasound (Electronic Edition)
2015;(4):288-295
- CountryChina
- Language:Chinese
-
Abstract:
ObjectiveTo explore the value of conventional echocardiography and transthoracic real-time three-dimensional echocardiography (RT3DE) in diagnosis of Ebstein anomaly.MethodsWe investigated the morphology and function of right ventricle (RV) as well as the structure, morphology and regurgitation of tricuspid valve in 61 adult patients with Ebstein anomaly before surgery by using conventional echocardiography and transthoracic RT3DE. Twenty normal adults were enrolled as control group. ResultsThe surface of the tricuspid leaflets, the morphology of the tricuspid annulus as well as the three-dimensional structure of the tricuspid valve were displayed stereoscopically by RT3DE. Complete RV volume data could be acquired in 32 patients of Ebstein anomaly. The apex or part of RV could not be contained in the remaining 29 patients. Thirty-four (55.7%) patients with Ebstein anomaly had severe tricuspid regurgitation,
16 (26.2%) patients had moderate to severe regurgitation, and 11 (18.1%) patients had moderate regurgitation. Compared with the normal adults, patients of Ebstein anomaly showed higher RV end-diastolic volume (EDV), end-systolic volume (ESV), end-diastolic volume index (EDVI), end-systolic volume index (ESVI), stroke volume (SV), RV anterior-posterior diameter (RV), tricuspid valve annular transverse diameter (TV-R), and lower RV ejection fraction(EF) [(273.5±77.7) mlvs (74.3±15.9) ml, (187.1±96.8) mlvs (31.1±9.2) ml, (177.4±53.6) ml/m2vs (43.4±8.2) ml/m2, (121.7±65.5) ml/m2vs (18.4±5.1) ml/m2, (95.9±20.2) ml vs (43.6±8.8) ml, (48.1±13.3) ml/m2vs (19.0±1.9) ml/m2, (56.4±8.9) ml/m2vs (28.5±4.3) ml/m2, (38.3±12.8) %vs (59.3±5.1) %, allP<0.05). The tricuspid regurgitant orifice flow cross-sectional area (EROA) were correlated positively with RV anterior-posterior diameter (r=0.691), ratio of RV and LV anterior-posterior diameter (RV/LV) (r=0.6471).ConclusionTransthoracic RT3DE is a feasible method in addition to conventional two-dimensional echocardiography in evaluation of tricuspid valve mophology and function, as well as RV volume and EF in adult patients with Ebstein anomaly.