Changes of lacrimal film after phacoemulsification
10.3980/j.issn.1672-5123.2015.4.27
- VernacularTitle:白内障超声乳化术对泪膜功能的影响
- Author:
Xiao-Peng, LI
;
Yan, LI
;
Jun-Jie, JIAO
;
Shuang WANG
;
Jing, LIU
- Publication Type:Journal Article
- Keywords:
cataract;
phacoemulsification;
tear film function;
corneal sensitivity
- From:
International Eye Science
2015;(4):669-671
- CountryChina
- Language:Chinese
-
Abstract:
AIM: To observe of cataract phacoemulsification and intraocular lens implantation in patients with postoperative tear film, and to explore its clinical significance.
METHODS: A total of 106 patients ( 140 eyes ) undergone phacoemulsification were randomly chosen. Subjective dry foreign body sensation were observed at six nodes of period 1d, 1, 2, 3wk, and 1mo. Corneal fluorescein ( FSC ) , basal tear secretion ( SIT ) and tear film break-up time ( BUT) were used to detect functional changes of the tear film. And the correlation between tear film stability and corneal sensitivity was analyzed.
RESULTS: Dry eye cumulative score of postoperative 1d, 1, 2wk was higher than preoperative ( t= 8. 53, P=0.000;t=6. 27, P=0. 000; t=9. 02, P=0. 000). There was no significant difference in dry eye cumulative score at postoperative 3wk, 1mo compared with preoperative ( t=1.91, P= 0. 824; t= 1. 27, P= 0. 069). Corneal epithelial fluorescein staining points of postoperative 1d, 1, 2wk were increased compared with preoperative (t=11. 64, P=0. 000;t=9. 61, P=0. 000; t=8. 87, P=0. 001). There was no significant difference in corneal epithelial fluorescein staining points of postoperative 3wk and 1mo compared with preoperative (t=2. 52, P=0. 746; t=1. 16, P=0. 094). Corneal sensitivity detection values of postoperative 1d, 1, 2wk were significantly higher than that of preoperative (t=9.61, P=0.000;t=9.27, P=0.000;t=11.39, P=0.024), and there was no difference postoperative 3wk and 1mo compared with preoperative (t=1. 19, P=0. 562;t=2. 17, P=0. 501).
CONCLUSION: Phacoemulsification with intraocular lens implantation will reduce the tear film stability in the short term, but after a long rest will be improved to a certain extent.