Amniotic membrane transplantation in the treatment of conjunctival rupture, dehiscence and socket contracture after hydroxyapatite orbital implantation
10.3980/j.issn.1672-5123.2014.12.48
- VernacularTitle:羊膜移植治疗义眼座植入术后结膜裂开伴结膜囊狭窄
- Author:
Xian-Yong, LIU
;
Jing-Yi, ZHUANG
;
Yi-Jing, XIN
- Publication Type:Journal Article
- Keywords:
amniotic membrane transplantation;
conjunctival rupture;
socket contracture;
exposure of orbital implants;
clinical effect
- From:
International Eye Science
2014;(12):2271-2273
- CountryChina
- Language:Chinese
-
Abstract:
AlM: To investigate the clinical effect of preserved amniotic membrane transplantation in the treatment to conjunctival rupture, dehiscence and socket contracture after hydroxyapatite ( HA) orbital implantation.
METHODS: ln 16 cases of conjunctival rupture and socket contracture after HA orbital implantation, conjunctival tension was release by operation and preserved amniotic membrane was transplanted on conjunctival scleral exposure area.
RESULTS:ln all cases, conjunctiva healing, completely cover the sclera and conjunctiva socket recover ideal depth after operation in 15 cases, 1 case was fail.
CONCLUSlON: Preserved amniotic membrane transplantation is an effective method to treat conjunctival dehiscence and keeping the ideal conjunctival socket depth after orbital implantation.