Application of functional-structural relationship between automated perimetry and retinal nerve fiber layer in the early diagnosis of open-angle glaucoma
10.3760/cma.j.issn.2095-0160.2013.11.018
- VernacularTitle:视网膜神经纤维层与视野的对应关系在开角型青光眼早期诊断中的应用
- Author:
Qing, ZHANG
;
Xiao-bo, XIA
;
Ping-bao, WANG
- Publication Type:Journal Article
- Keywords:
Glaucoma;
Visual field;
Retinal nerve fiber layer;
Sensitivity;
Specificity
- From:
Chinese Journal of Experimental Ophthalmology
2013;32(11):1079-1084
- CountryChina
- Language:Chinese
-
Abstract:
Background One of the difficulties in identifying early glaucoma is the variability of perimetry performance.For this reason,a field defect have to be reproduced more than two consecutive examinations before it is confirmed.The relationship between visual field sensitivity and retinal nerve fiber layer (RNFL) thickness may give us a more efficient and objective assessment to the early diagnosis of glaucoma.Objective This diagnostic test was to evaluate the application of functional-structural relationship between automated perimetry and RNFL in the early diagnosis of open-angle glaucoma.Methods Sixty-four eyes of 64 patients with early open-angle glaucoma and 50 eyes of 50 normal volunteers with the matched age and gender were enrolled in Xiangya Hospital January to June 2007.Visual field examinations,including standard automated perimetry (SAP),short wave automated perimetry (SWAP),and imaging of scanning laser polarimetry with variable corneal compensation(GDxVCC),were performed on the subjects with the informed consent.The sensitivity and specificity of the joint or single measurement of GDxVCC,SAP and SWAP under the local diagnostic criteria,and overall diagnostic criteria were calculated.Results According to the overall diagnostic criteria,the sensitivity of GDxVCC,SWAP and SAP were 70%,63%,61% respectively,and the specificity were 84%,80%,78%,respectively.According to the local diagnostic criteria,the sensitivity of GDxVCC,SWAP and SAP were 78%,86%,78%,respectively,and the specificity were 54%,40%,50%,respectively.With the local diagnostic criteria,the sensitivity and specificity of serial test of GDxVCC,SWAP and SAP were 86% and 90% respectively,and the positive likelihood ratio and negative likelihood ratio were 8.59 and O.16,respectively.Conclusions The functional-structural relationship between automated perimetry and RNFL which can provide valuable individual diagnostic information for patients,and serial test of GDxVCC,SWAP and SAP can reduce the false positive rate and improve the diagnostic performance significantly.