Clinical efficacy of coaxial phacoemulsification through a 1.8 mm microincision for cataract surgery
10.3760/cma.j.issn.2095-0160.2013.04.012
- VernacularTitle:1.8 mm同轴微切口白内障超声乳化摘出术的临床观察
- Author:
Wei, CUI
;
Zhi-ying, LIU
;
Wei, GAO
;
Qiang, LU
;
Xiao-cheng, MA
- Publication Type:Journal Article
- Keywords:
Phacoemulsification surgery;
Cataract;
Minimally invasive surgery
- From:
Chinese Journal of Experimental Ophthalmology
2013;(4):362-364
- CountryChina
- Language:Chinese
-
Abstract:
Background With the development of phacoemulsification surgery,the minimization of the size of the incision in order to reduce the damaging of eye tissue and postoperative complications becomes a focus.Objective This study aimed to assess the clinical efficacy of coaxial phacoemulsification type cataract surgery through a 1.8 mm microincision with foldable intraocular lens (IOL) implantation in eyes with age-related cataract.Methods Informed consent was obtained from each patient at the beginning of this study.A serial case observation study was designed.Thirty-two eyes of 32 patients with age-related cataract were enrolled in the Inner Mongolia Autonomous Region People' s Hospital from April 2012 to May 2012,including 8 eyes of grade Ⅱ hard nucleus cataract,16 eyes of grade Ⅲ hard nucleus cataract and 8 eyes of grade Ⅳ hard nucleus cataract.Ocular axial length was measured by an A-mode ultrasonic apparatus,and IOL diopter was calculated using the SRK-Ⅱ formula.Under ocular surface anesthesia,a 1.8 mm clear corneal tunnel incision was made at the 10-11 o' clock position,and then an auxiliary incision was made at the 2 o' clock position.The opaque lens was extracted by routine phacoemulsification.An Akreos MI60 IOL was implanted through the 1.8 mm incision.The time and level of ultrasonic power required for phacoemulsification,postoperative visual acuity and incidence of postoperative complication were assessed.Postoperative examinations were scheduled at 1 day,1 week and 1 month after the surgery.Results All the operations proceeded smoothly.The mean phaco-time was (7.0±3.6) seconds and the mean ultrasonic power level was (15.3 ±6.1)% among the different grades of cataract groups.The number of eyes presenting an uncorrected distance visual acuity of ≥ 0.5 was 18 (56.25%),28 (87.50%) and 30 (93.75%) 1 day,1 week and 1 month after surgery,respectively.The number of eyes with a best corrected distance visual acuity of ≥ 0.5 and 0.8 were 31(96.88%) and 26 (81.25%),respectively,1 month after surgery.Negligible changes were detected in the anterior chamber depths,and no thermal damage was found at the incision during the operation.Conclusions Coaxial phacoemulsification and IOL implantation through a 1.8 mm microincision is safe and effective.Thorough planning and precise execution are necessary.