Comparision of STIC-Multiplanar mode and two-dimensional ultrasound in the routine scanning of fetal heart
10.3877/cma.j.issn.1672-6448.2013.06.009
- VernacularTitle:胎儿心脏时间空间关联成像联合多平面模式与二维超声的对比研究
- Author:
Sai-hui, MOU
;
Ying, WU
- Publication Type:Journal Article
- Keywords:
Ultrasonography,prenatal;
Spatio-temporal image correlation;
Multiplanar mode
- From:
Chinese Journal of Medical Ultrasound (Electronic Edition)
2013;(6):470-474
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the clinical application of spatio -temporal image correlation combined with multiplanar mode (STIC-MP) in the routine scanning of normal fetal heart ,and to provide evidence for the application of STIC in the routine scanning of fetal heart in second trimester .Methods One hundred pregnant women at 20-27 weeks′gestation were enrolled.The routine five views of normal fetal heart were examined and recorded by two-dimensional ultrasound,and the volume datasets were acquired with STIC.The time of picture storing and the fetal cardiac structures were recorded respectively .The quality of pictures obtained by both methods were compared by the scoring system .The imaging method of STIC-MP was explored and analyzed.Results Satisfactory gray-scale volume acquisitions were accomplished in all 100 cases.The quality of the four views(four chamber view,left outflow tract,right outflow tract,three vessel-trachea views) derived from volume datasets were comparable to that directly obtained from two-dimensional scanning.No significant difference of visualization rate ( χ2 =3.030,0.337,2.010,0.000,all P>0.05)was found between the STIC-MP(100/100,98/100,98/100,95/99 as 100.0%,98.0%,98.0%,96.0%)and two-dimensional(97/100,99/100,100/100,95/98 as 97.0%,99.0%,100.0%,96.9%).However,the difference of visualization rate was found in the stomach transverse view ( χ2 =9.776,P=0.001).The mean time for the examination and picture saving of fetal cardiac structures by STIC ,mean acquisition time was (1.17 ±0.52) min,which was much shorter than that by two-dimensional scanning (4.20 ±1.35) min (t=0.38,P<0.05).The mean time for obtaining the routine five views of fetal heart and analyzing by STIC and MP were (6.75 ±1.51) min,(1.35 ±0.30)min respectively,which was longer than (4.20 ±1.35)min and (0.83 ±0.22)min by two-dimensional ultrasound(t=11.75,11.75,both P=0.00).Conclusions STIC-MP simplifies the picture-gathering process,decreases the ultrasound exposure upon fetal heart obviously .No significant difference was found between the quality of the five views obtained from STIC-MP and two-dimensional ultrasound.The views of STIC-MP can satisfied the routine scanning of fetal heart ,although the interpretation time of STIC-MP was longer compared with two-dimensional ultrasound.There will be vital significance on the use of STIC in clinical application .