Correlation between anterior chamber angle diameter and ciliary sulcus distance measured by Suowei panoramic 50-MHz digital ultrasound blomicroscopy
10.3760/cma.j.issn.2095-0160.2011.10.013
- VernacularTitle:全景超声生物显微镜对人眼睫状沟距离及前房直径的测量
- Author:
De-jiao, LI
;
Ning-li, WANG
;
Da-peng, MU
- Publication Type:Journal Article
- Keywords:
Acoustie/ultrasound biomicnoscopy/panoramic;
Anterior chamber;
Ciliary sulcus;
Lens/intraocular;
Bio-measurement
- From:
Chinese Journal of Experimental Ophthalmology
2011;29(10):918-921
- CountryChina
- Language:Chinese
-
Abstract:
Background Measurement of ciliary sulcus distance is important for phakic intraocular lens implantation.Suowei panoramic 50-MHz digital ultrasound biomicroscopy makes it possible for the direct measurement of ciliary sulcus distance.Objective The aim of this study was to investigate the correlation between anterior chamber(AC)angle diameter and ciliary sulcus distance in different AC depth population and offer a clinical guide.Methods The anterior chamber angle diameter and ciliary sulcus distance were measured in 30 right eyes with shallow anterior chamber caused by suspect glaucoma and 30 right eyes with deep anterior chamber dut to the high myopia with Suowei panoramic 50-MHz digital ultrasound biomicroscopy.Three horizontal B-scans with the focal plane approximately at a depth corresponding to the iris plane were acquired for each eye.The differences of the anterior chamber angle diameter and ciliary sulcus distance were calculated and compared between the two groups.The correlation of the anterior chamber angle diameter and ciliary sulcus distance were evaluated in respective group.Results In shallow AC group,the mean angle diameter was(11.49+0.75)mm,the mean ciliary sulcus distance was (10.97±0.86)mm with the mean standard deviation of the difference of(-5.14± 0.55)mm,showing a statistically significant difference(t =-5.092,P =0.000).In shallow AC group,linear regression analysis showed a statistically significant correlation between ciliary sulcus distance and angle diameter(R2=0.593,P=0.000)and the Pearson's correlation coefficient was 0.767.In deep AC group,the angle diameter was(12.69±0.67)mm;while ciliary sulcus distance was(12.31 ± 0.61)mm with the mean slandard deviation(-0.38 ± 0.17)mm,which was statistically significantly different(t=-5.531,P=0.000).The ciliary sulcus distance was found to be linear correlation with the angle diameter(R2 =0.699,P=0.000)and Pearson' s correlation coefficient of 0.836.Conclusions Panoramic ultrasound biomicroscopy is an useful tool to the measurement of ciliary sulcus distance.This study exhibited that the ciliary sulcus distance is significant associated with the anterior chamber angle diameter,which may offer a guide for phakic intraocular lens implantation.