Evaluation of 99mTc labeled diadenosine tetraphosphate as an atherosclerotic plaque imaging agent in experimental models.
- Author:
Wei, CAO
;
Yongxue, ZHANG
;
Rui, AN
- Publication Type:Journal Article
- From:
Journal of Huazhong University of Science and Technology (Medical Sciences)
2006;26(3):278-80
- CountryChina
- Language:English
-
Abstract:
The potential of 99mTc labeled P1, P4-di (adenosine-5')-tetraphosphate (Ap4A) for imaging experimental atherosclerotic plaques was evaluated in New Zealand white (NZW) rabbits. To label the 99mTc to Ap4A, stannous tartrate solution was used. 99mTc-Ap4A was purified on a Sephadex G-25 column. The radiochemistry purities of 99mTc-Ap4A were 85% to 91%. Biodistribution study revealed 99mTc-Ap4A cleared from blood rapidly. Thirty min after 99mTc-Ap4A administrated on NZW atherosclerotic rabbits, lesion to blood (target/blood, T/B) ratio was 3.17 +/- 1.27, and lesions to normal (target/non-target, T/NT) ratio was 5.23 +/- 1.87. Shadows of atherosclerotic plaques were clearly visible on radioautographic film. Aortas with atherosclerotic plaques also could be seen on ex vivo gamma camera images. Atherosclerotic abdominal aortas were clearly visible on in vivo images 15 min to 3 h after 99mTc-Ap4A administration. 99mTc-labeled Ap4A can be used for rapid noninvasive detection of experimental atherosclerotic plaque.